As the global population grows, the need for more efficient swine production solutions becomes increasingly important. With over 30 years of industry experience, AP (Automated Production Systems) is positioned to support this ever growing demand across the globe. AP is committed to delivering comprehensive solutions by providing you with equipment that works as hard as you do.

Inlets

AIRFLOW DISTRIBUTION

Inlets

Inlets

AIRFLOW DISTRIBUTION

Highlights

  • Air inlets and tunnel doors provide precise control and distribution of airflow into or out of any type of ventilation system.
  • Energy savings and low maintenance.
  • Power washer friendly.
  • Corrosion resistant construction.

Built to Perform

Actuated Ceiling Inlets

Actuated Ceiling Inlets

Actuated ceiling inlets are available in a 2500 to 4000 CFM bi-directional or 2500 CFM uni-directional models and with stainless steel or plastic housings.

Actuated PVC Wall Inlets

Cut to length on site for a customized-fit

Actuated PVC Wall Inlets

Opens automatically based off negative static pressure supplied by the exhaust fans. Available in bi-fold or four-sided models for ceiling inlets, and in top-hinged counter-balanced model for wall inlets. Corrosion-resistant plastic and aluminum housing and doors. Hardware package and insulation stop with every inlet. Panel dimensions are 1.5" thick x 30" tall x 24’ long.

Adjust-A-Baffle™ Systems

Adjust-A-Baffle™ Systems

Constructed of one-inch thick polystyrene with a rugged plastic coating fastened to UV-stabilized PVC channels. Any length possible in 8", 12", 16", 18", and 24" sizes. Flexible PVC hinge and sealing strip slide into the PVC channels. Stainless steel cable or rod hardware packages available.

Non-Actuated Ceiling and Wall Inlets

Bi-flow ceiling inlet sizes: 1000 & 2700 CFM

Non-Actuated Ceiling and Wall Inlets

Non-actuated ceiling and wall inlets models are available with plastic or aluminum housing. The counter-weighted baffle system allows the 12" baffle to become automatic without the use of mechanical static pressure control.

Specifications

Maximum Inlets Per Actuator & Maximum Run Length

Actuator Type Max. Number of Inlets Per Controller (1:1 Pulley Ratio) Max. Number of Inlets Per Controller (2:1 Pulley Ratio)
Max. Run Length (ft.)
Auto-Air Controller 16 24 150
Curtain Controller 48 72 150

* for maximum accuracy, limit run length to 150 feet.

Rated Airflow Inlet Opening Actuator Travel

  Inlet Positioning at Full CFM Rating Inlet Positioning Restricted to Horizontal
Inlet Model

Rated CFM @0.10 Static Pressure Maximum Opening (in.) Rated CFM @0.10 Static Pressure

Opening at horiz. (in.)
ACI-2-4000 4000 8.0 2400 4.5
ACI-2-1500
2000 8.0 1400 4.5
ACI-4000P2
4100 8.0 2500 4.5
ACI-2500P2
2200 8.0 1500 4.5
ACI-2-3000
3100 12.0 2100 5.0
ACI-1-2500
2500 12.0 1150 5.0
ACI-2700P
2400 9.0 N.A. N.A.

Refer to the actuator manual to set limit switches in the actuator for the proper amount of travel needed.

If the pulley ratio is 1:1 the travel needed in the actuator is the same as the maximum opening listed above.